期刊文献+

碳纤维筋(CFRP筋)松弛损失试验研究 被引量:16

Experiment Study on Relaxation Losses of CFRP Tendons
下载PDF
导出
摘要 探讨碳纤维筋的松弛特性,试验研究国产8碳纤维筋松弛损失,得出了碳纤维筋松弛损失的计算公式。 In this article, authors discuss the relaxation characteristic of CFRP tendons.The relaxation losses of 8 CFRP tendons produced in China were tested,and the empirical formula for calculation of the relaxation loss was proposed with the regressive method.
出处 《施工技术》 CAS 北大核心 2005年第7期40-41,53,共3页 Construction Technology
关键词 碳纤维筋 松弛损失 预应力 试验研究 CFRP tendon relaxation loss prestress experimental study
  • 相关文献

参考文献3

  • 1陶学康,孟履祥,关建光,徐福泉.纤维增强塑料筋在预应力混凝土结构中的应用[J].建筑结构,2004,34(4):63-71. 被引量:25
  • 2Hamid Saadatmanesh,Fares E Tannous.Relaxation,creep,and fatigue behavior of carbon fiber reinforced plastic tendons[J].ACI Materials Journal,1999.
  • 3JSCE-E 534-1995,Test method for long-term relaxation of continuous fiber reinforcing materials[S].

二级参考文献16

  • 1ACC俱乐部广报委员会.Advanced composite cables[Z].ACC俱乐部事务局,2002,10..
  • 2Somboonsong W, KO F K, Harris H G. Ductile hybrid fiber reinforced plastic reinforcing bar for concrete structures: design methodology. ACI Materials Journal, November-December,1998.
  • 3Grace N F, Navarre F C, Nacey R Bet al. Design-construction of Bridge Street Bridge- First CFRP bridge in the United States.PCI Journal,September-October, 2002.
  • 4Vervuurt A H J M, Kaptijn N, Grundlehner W B. Carbon-based tendons in the Dintelhaven Bridge. the Netherlands, Structural Concrete,2003,4( 1 ).
  • 5Concrete engineering series 23. Recommendation for design and construction of concrete structures using continuous fiber reinforcing materials. JSCE, 1997.
  • 6Tadros G. Provisions for using FRP in the Canadian highway bridge design. Concrete International, July,2000.
  • 7Dolan C W, Hamilton III H R, Balls C E, et al. Design recommendation for concrete structures prestressed with FRP tendons.FHWA DTFH61-96-C-00019, Aug., 2001.
  • 8Reda Taha M M, Shrive N G. New concrete anchors for carbon fiber-reinforced polymer post-tensioning tendons-Part 1 : State-of-the-art review/design. ACI Structural Journal, 2003,100(1).
  • 9Reda Taha M M, Shrive N G. New concrete anchors for carbon fiber-reinforced polymer post-tensioning tendons-Part2: Develop-ment/experimental investigation. ACI Structural Journal, Jan.-Feb,2003,100( 1 ).
  • 10Rostasy F S. FRP tensile elements for prestressed concrete-State of the Art, Potentials and Limits. Fiber-Reinforced-Plastic Reinforcement for Concrete Structurs,ACI SP-138,1993.

共引文献24

同被引文献167

引证文献16

二级引证文献82