期刊文献+

可吸收螺钉及固定棒(SR-PGA、PLLA)临床应用的初步报告 被引量:107

The Use of Self-reinforced Absorbable (SR-PGA。PLLA )Screws and Rods for Fracture Treatment:APreliminary Report of Tec Cases
原文传递
导出
摘要 作者采用SR-PGA、PLLA可吸收螺钉、固定棒手术治疗踝关节骨折5例(WeberB型3例、C型2例)、跖骨基底骨折1例、肱骨髁上骨折1例、桡骨骨折1例、Barton骨折1例、外翻1例。10例患者均获随访,平均随访时间6.2个月。疗效判断以局部功能判断和术后不同时期影像学检查综合判断。结果优8例、良1例、可1例。全部病例骨折均固定至愈合无移位,无伤口感染。作者认为:SR-PGA、PLLA材料的可吸收内固定物是松质骨骨折、尤其踝关节骨折较理想的内固定物。 AbstractThe authors reported their preliminary experiencehthe t reatment of fractu res wit h self-reinforced ab-sorbale (SR-PGA,PLLA)serews and,rods. Therewere 5 cases of ankle fractures (Weeber B 3 cases and C2cases),hasal metatarsal fracture l case,supracondylarfracture of humerus 1 case, fracture of the radius lcase,Barton’s fracture l case and osteotomv of the first metatarsal bone in hallux valgus operation l case. Func-tional recovery and the radiographical appearance in thefollow-up showed excellent results in 8 cases , good in lcase and fair in l case,The fract ure s were all healedwit hout displacement and infection, The authors be-lieve,the absorbable SR-PGA,PLLA screw and rodwere excellent implant for fixation for fractures of can -cellous bone and especially for the fractures of the ankle.
出处 《中华骨科杂志》 CAS CSCD 北大核心 1995年第11期755-757,共3页 Chinese Journal of Orthopaedics