期刊文献+

腔体微扰法测厚度的分辨率和误差 被引量:1

The Resolution and Error of the Thickness Measurement by Microwave Cavity Perturbation
下载PDF
导出
摘要 讨论了用微波腔体微扰方法测厚度的分辨率.计算及实验均表明,腔体微扰方法测量厚度具有高的分辨率(0.2μm),文中分析了整机产生误差的主要原因和减小误差的方法,指出扫频源的非线性对精度和稳定性的影响。 The principles of thickness measurement .and thiknees resolution of plastic film by microwave cavity parturbation were discussed. The calculated and experimental results showed that the thickness measurement with cavity perturbation had high resolution (0.2μm). The main causes of error were analysed and the methods of error reduction was examined. The dependence of accuracy and stability of instrument on the linearity of microwave sweep generator were discussed emphatically.
作者 吕文选
出处 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 1989年第1期39-43,共5页 Journal of Xiamen University:Natural Science
关键词 腔体微扰 厚度 误差 分辨率 Cavity perturbation, Thickness resolution, Error
  • 相关文献

参考文献6

  • 1李焯,厦门大学学报,1988年,27卷,299页
  • 2杨进成,厦门大学学报,1988年,27卷,176页
  • 3吕文选,电子测量技术,1987年,3期,6页
  • 4周在杞,仪器仪表学报,1986年,7卷,103页
  • 5杨国渝,微波,1985年,1期,47页
  • 6魏耀明,厦门大学学报,1979年,8卷,86页

同被引文献3

  • 1钟茂声,吕文选,李焯,杨进城.简易式微波腔体微扰法介质薄膜厚度仪[J]电子测量与仪器学报,1988(01).
  • 2吕文选,肖芬,戴丽明.微波耿氏边际振荡器在测量介质介电常数等的应用[J]厦门大学学报(自然科学版),1986(04).
  • 3魏耀明,夏德昊,陈祥福,钟茂声,吕文选.微波谐振腔微扰法测湿仪的研制[J]厦门大学学报(自然科学版),1979(04).

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...