摘要
应用StalbergE的干扰型分析技术,对10例正常人和20例神经肌肉疾病患者进行了传统肌电图和干扰型分析检测。结果表明该分析技术较之常规的运动单位定量分析具有快捷、准确率高的优点。
Using analysis of interference patterns by Stalberg, we engaged in tranditional quantitatingelectromyographic analysis and electromyographic interference patterns analysis(IPA) from 10 normal subjects and 20 patients with neuromuscular disorders. The results revealed that IPA was faster and more accuracy than tranditional quantitating electromyography.
出处
《中华物理医学杂志》
CAS
CSCD
1995年第1期38-40,共3页
Chinese Journal of Physical Medicine and Rehabilitation
关键词
干扰型分析
肌电图
神经肌肉疾病
interference patterns analysis (IPA)
quantitative electromyography
motor unit action potentials