摘要
为了及时对糖尿病肾病进行早期诊断,建立了一种敏感、简便、可靠的尿微量转铁蛋白(TRF)酶免疫测定法。工作范围0.5~128μg/L,检出限0.26μg/L,批内变异系数(CV)6.3%,批间CV8.8%,回收率97.3%。80例正常健康人的尿TRF值以μg/mmolCr表示,其均数、几何均数、中位数和95%位数分别为44.9、36.1、32.3和127.5。正常人、糖尿病和肾小球疾病的尿TRF和尿白蛋白(A1b)之间均呈现显著正相关性(r=0.60~0.86,P<0.01~0.001);疾病组中,尿TRF增高幅度较尿Alb增高幅度大。尿TRF是一种肾小球滤过功能不全的敏感指标。
e have depveloped an enzyme immunoassay for microtransferrinuria,This assay was simple,sen-sitive and reliable. The working rang was 0.5 to 128μg/ml, the detection limit 0. 26μg/Land within-and between-assay CV were 6.3%and 8.8%respectively. The mean,geometric mean and median oftransferrinuria in a group of 80 healthy subjects were 44.9, 36.1 and 32.3μg/mmol Cr respectively and the 95th percentile was 127.5μg/mmol Cr. Correlation coefficients between transferrinuria and albumin-uria in healthy subjects,diabetics and glomerulopathy were 0. 6 to 0. 86.The urinary excretion of trans-ferrin was more elevated than that of Albumin. Excretion of transferrin in urine is a sensitive index ofthe glomerular dysfunction.