期刊文献+

各向异性基岩的热学性能参数的野外现场测定探讨 被引量:1

Study on the Field Determination of Thermal Parameters of Rock Mass
下载PDF
导出
摘要 本文针对基岩的热学性能具有各向异性的特点,根据热传导的基本原理和热胀冷缩的规律,进行野外现场试验,实测温度场及变形量。运用“反演”方法分别推求其导热系数λ和线胀系数a.并编制程序来进行数据处理。结果表明,通过此方法可测定各向异性岩体的λ和a.方法精度较高,而且方便实用。可用于探讨现场岩体的热学性能参数的变化规律,及为实际工程提供较为可靠而合理的资料。 In this paper,according to the heterogeneous the rmal characteristics of the foundation rock mass,based on the theory of heat conduction and the principle of theimal expansion and shrinkage,the fieldtestings are conducted to measure the temperature and the deformation of the rock mass. Thus the ther-mal conductivity and the linear expansion coefficient are calculated inversely,and a computational pro-gram is made to deal with the data,The results show that the method is of high precisim and is muchconvenient, and can provide the reliable and more reasonable data
机构地区 重庆建筑大学
出处 《重庆交通学院学报》 CAS 1995年第4期62-68,共7页 Journal of Chongqing Jiaotong University
关键词 基岩 野外现场试验 各向异性 导热系数 热学性能 he foundation rock,the field testing, anisotropy, heat conductivity,linear cxpansion coeffi-cient
  • 相关文献

参考文献2

  • 1王补宣,王仁.含湿建筑材料的导热系数[J]工程热物理学报,1983(02).
  • 2王补宣,任泽霈.利用“平板导热仪”测定热绝缘材料导温系数α的探讨[J]工程热物理学报,1981(03).

同被引文献10

  • 1杨强生,浦保荣.高等传热学[M].2版.上海:上海交通大学出版社,2001
  • 2HolmanJP.传热学[M].英文版.北京:机械工业出版社,2005.
  • 3Shiah Y C and Tan C L. BEM treatment of three-dimensional ani- sotropic field problems by direct domain mapping[ J] 1. Engineering Analysis with Boundary Elements,2004,28:43-52.
  • 4Hiroaki T, Masaya O, Hideki T, et al. Thermal characteristics of a double-glazed external wall system with roll screen in cooling sea- son [J ]. Building and Environment,2009,44 : 1509-1516.
  • 5Hashemi N, Fayaz R, Sarshar M. Thermal behaviour of a ventilated double skin facade in hot arid climate [ J ]. Energy and Buildings, 2010,42 : 1823-1832.
  • 6Ding W T, Hasemi Y, Yamada T. Natural ventilation perfolnance of a double-skin facade with a solar chimney [ J ]. Energy and Buildings, 2005, 37:411418.
  • 7Wong N H,Wang L, Aida N C, et al. Effects of double glazed fa- cade on energy consumption, thermal comfort and condensation for a typical office building in Singapore [ J ]. Energy and Buildings, 2005,37 : 563-572.
  • 8Wong P C ,Parsad D,Behnia M. A new type of double skin facade configuration for the hot and humid climate[ J]. Energy and Build- ings, 2008,40 : 1941-1945.
  • 9Kim Y M, Kim S Y,Shin S W,et al. Contribution of natural venti- lation in a double skin envelope to heating load reduction in winter [ J ]. Building and Environment ,2009,44:2236-2244.
  • 10刘志宏,李俊明,王补宣,徐鹏.外循环式双层玻璃幕墙的热工性能研究[J].建筑科学,2010,26(4):75-79. 被引量:6