期刊文献+

径迹法累积测定室内外氡浓度 被引量:1

Passive Integrating Measurement of Indoor and Outdoor Radon Concentrations
下载PDF
导出
摘要 使用CR-39探测器和探杯型氡监测器,对本所办公楼地下室及办公室内外氡浓度进行2—6个月春夏秋冬不同季节的累积测定。对收集后的CR-39随机扫描读数方式对结果的影响做了比较。结果表明地下室氡浓度高于其他层,室内高于室外,除个别情况外,随机扫描的影响在统计涨落范围内。 Both indoor and outdoor 222Rn concentrations ofan office building in Zhongguancun, Beijing,were determined by using a CR-39 detector andpassive integrating radon monitor in different seasons of spring, summer, autumn and winter,with a total sampling time of 2- 6 months.Theresults show that the radon level found in thebasement was higher than that in the office roomsabove the basement and the indoor radon levelswere higher than the outdoor radon levels. Theerror sources, including the effects of CR-39 random scanning and reading ways on the results ofdetermination, were also discussed. It was foundthat, except in some individual cases, the extentof influence caused by different scanning wayswas within the range of statistical variation.
作者 翟鹏济
出处 《环境科学》 CAS CSSCI CSCD 北大核心 1995年第2期65-66,66,共3页 Environmental Science
关键词 氡浓度 CR-39探测器 径迹法 测定 radon, concentration, α tracks, CR39 detector
  • 相关文献

参考文献4

  • 1田志恒,左富琪,肖德涛.驻极体测氡法及其应用[J].原子能科学技术,1993,27(1):57-61. 被引量:2
  • 2翟鹏济,原子能科学技术,1993年,1期,74页
  • 3庞德聆,第四届全国固体核径迹探测器会议论文集,1990年
  • 4张政国,第四届全国固体核径迹探测器会议论文集,1990年

二级参考文献1

共引文献1

同被引文献1

引证文献1