摘要
利用NP—多胺基磷酸树脂为填料制作浓缩柱,结合流动注射技术,对铜渣、尾矿渣及电镀污泥浸出液中的微量铅和镉进行富集,用火焰原子吸收法测定。对于铅和镉,其精密度实验的相对标准偏差分别为2.7%~11.4%和1.5%~4.0%;回收率分别为93.7%~103.0%和88.4%~92.8%。
Trace lead and cadmium in leaching liquors of copper slag, tailing and electroplating sludge were pre-concentrated with concentration column preqared by NP-401 type chelating resin and determined by FAAS with sample introducing by injection technique. For lead and cadmium, the relative standard deviation were 2.7-11.4% and 1.5-4.0%, the recoveries were 93.7-103% and 88.4-92.8% respectively.
出处
《上海环境科学》
CAS
CSCD
1995年第8期27-28,46,共3页
Shanghai Environmental Sciences
基金
国家八.五环保科技攻关项目(85-909-05-01)资助课题
关键词
固体废物
原子吸收光谱法
流动注射
环境化学
Environmental monitoring Lead Cadmium On-line pre-concentration Flow injection Flame AAS Solid waste