期刊文献+

安钢2号高炉护炉实践 被引量:1

Lining protection on No2 blast furnace of Anyang Iron & Steel Co.
下载PDF
导出
摘要 安钢2号高炉在1993年6月25日到10月1日实施护炉,取得了如下效果:铁口合格率由6月中下旬的30%提高到100%;炉缸水温差平均由4.8℃降到1.5℃;炉况稳定,冶强提高,指标改善。所采取的护炉措施包括强化炉前管理、改善炉内操作、强化炉缸冷却等。 The lining protection was carried out by means of strenghtening casthouse operation management,improving BF operation,intensifying hearth cooling and so on from June 25th to October 1st in 1993 on No2 BF of Anyang I & S Co.As a result,the percent of standard taphole arose from 30% to 100%,the average difference between inlet and outlet cooling water temperatute in hearth was reduced from 4.8℃to 1.5℃,as well as the stabilized furnace condition,increased smelting intensity and improved technical and economic indexes were achieved.
机构地区 安钢炼铁厂
出处 《炼铁》 北大核心 1995年第A01期34-36,共3页 Ironmaking
关键词 高炉 护炉 炉缸 衬砖 medium sized blast furnace,lining protection,measures,effect
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部