摘要
现行砼结构设计规范(GBJ10-89)关于预应力砼构件预拉区的计算与构造规定,在使用上并不简便;理论上有缺陷、在有些情况下,降低结构可靠度作者根据自已的研究结果作了对比论证,提出修改设计计算方法的建议.
Using the provisions of calculation and construction on the prestressed concrete members after transfer in the concrete structure code (GBJ 10-89) were inconvenient. There are some shortcomings about the provisions in theory so that the reliability would be reduced in some cases. The study results by the author were in comparison with these provisions. and he puts forward the propositions to modify the calculated methods.
出处
《上海大学学报(自然科学版)》
CAS
CSCD
1995年第6期616-625,共10页
Journal of Shanghai University:Natural Science Edition
关键词
预拉区
混凝土结构
预应力混凝土
混凝土构件
tension zone after transfer
precompressed tensile zone
allowable calculated stresses.