摘要
在两级电点火装置上,利用高压脉冲电源进行了HAN基液体发射药的电点火实验。实验研究了实现无电弧点火、限制电弧放电所需的电源特性参数及点火结构参数,其结果为液体发射药电点火器设计提供了依据。
A high current/voltage pulse former is used in two-stage electric igniter to transfer the electrical energy to the electrodes.LP1846in the precombustion chamber is initiated by discharging a high current pulse between a pair of coaxial electrodes,antechamber containes an additional LP booster charge.For the complete ignition of LP1846.areless discharge and arc discharge occur in different phase of ignition.In order to initiating the LP without arc formation,the effects of ignition configuration parameters,pulse electrical characteristics on the electrical energy releasing process and burning properties have been investigated.The research results provide the basis for the design of electrical igniter.
出处
《弹道学报》
CSCD
1995年第4期36-41,共6页
Journal of Ballistics