摘要
杂多酸型载体与常规的四苯硼等型载体相比,电极性能具有独特的优点,用于乙醇等有机溶液中的药物测定,无明显的亚Nernst效应。
Drug ion-selective electrodes made with hetero-poly anion as exchange site exhibit better performances than the respective electrodes of conventional tetraphenylboron type, yielding low detection limits and fast responses. Functions of propantheline, berberine, dibazol, thiamine, streptomycin, moroxydine, tetracycline, oxytetracycline, doxycycline, erythromycin, carbetapentane, benzydamine, tetramisole and trifluoperazine electrodes are reported. The electrodes can be used in potentiometric determinations of the respective drugs in aqueous solutions, urine and mixtue of water and organic solvents.
出处
《药学学报》
CAS
CSCD
北大核心
1989年第6期458-464,共7页
Acta Pharmaceutica Sinica
基金
国家自然科学基金