摘要
惯性常数是电力系统暂态稳定计算中的重要参数。本文详述了这一参数的两种定义,惯性常数对暂态稳定的影响以及抑制惯性常数偏小的不良后果的各种实用、有效措施。
Inertia constant of generating unit is animportant parameter in transient stability calculationof power system, Two different definitions of this pa-rameter are explained in detail. The bad result of tran-sient stability will be caused by the small inertia con-stant of the generating unit. Some functional and ef-fective measures can be used to rextrain or onset the-bad influences due to small inertia constant.All of thisare describedin this paper,
出处
《电网技术》
EI
CSCD
北大核心
1995年第5期59-61,共3页
Power System Technology
关键词
暂态稳定
发电机
电力系统
Inertia constant Transient stability Electric braking