摘要
通信设备用蓄电池组的浮充电压选择为每只电池2.15~2.23V,蓄电池在此电压下浮充运行,能保证供给通信设备的直流电压安全可靠,蓄电池既不过充电,又不产生小电流放电.从而可减少维护工作量,节约能源,保证蓄电池的有效容量,延长使用寿命,节约资金.
This paper describs the selection of float-charge voltage for lead acid batteries in communication application. For the flooded type batteries manufactured by Chongqing Storage Battery Factory,control of float-voltage of 2. 15-2. 23V per cell make it neither overcharge nor small discharge in float service,also,the features of low-maintenance,effective capacity,long life,safe and economization are satisfied.
出处
《电源技术》
CAS
CSCD
北大核心
1995年第6期15-17,共3页
Chinese Journal of Power Sources
关键词
铅酸蓄电池
低压浮充供电
蓄电池
lead acid storage batteries,low voltage float charging,voltage percell