在前文中曾提出,第一终点PH>3.7的情况下,以多元酸标准溶液的半中和点为第一点,测定各组分酸含量的方法。在此基础上,本文在理论上明确了影响各组分酸含量测定的因素,从而提出第一终点PH不同的情况下,Ka1/Ka2倍数不同时可准确滴定的Ve2/V^Te值的计算方法。实验结果表明,在此条件下结果是可靠的。
In the previous paper, we proposed a method for determining each acid content byhalf neutralization point(or 1/3 neutralization point) of standard solvent of polybasic acids as the first terminal point, when the pH value of first terminal point is over 3. 7. On the basis of this, we defined the factors which affect the determination of each acid content theoretically and then proposed the calculating method for determining the value of Ve2/VeT accurately when the value of Ka1/Ka2 is different. the test showed that result is reliable in this condition.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1995年第9期1051-1054,共4页
Chinese Journal of Analytical Chemistry
关键词
强酸
多元酸
混合酸
组分
滴定法
Strong acid, polybasic acid, mixed acid, titrimetry