期刊文献+

脉冲多普勒信号的模拟方法 被引量:1

The simulation method of pulsed Doppler signal
原文传递
导出
摘要 脉冲多普勒技术已经成为医学临床无损检测血流的一种有效手段.利用计算机模拟的脉冲多普勒信号,可以为各种脉冲多普勒信号处理方法的研究提供信号源,从而了解各种不同处理方法的性能.文中提出一种脉冲多普勒信号的模拟方法,它可以从信号的平均频率曲线和频谱带宽出发,合成正常血流和异常血流下的脉冲多普勒信号,为从脉冲多普勒信号研究血流中的湍流和涡流提供了便利. Pulsed Doppler ultrasound has become a valuable tool in the noninvasive measurement of flow in the medical clinic. Pulsed Doppler signals simulated in computer can be used as the signal resource in the research of pulsed Doppler signal processing,which can make it possible to compare the perfomance of different processing methods.A simulation method of pulsed Doppler signal is described in this paper. This simulation model is based on the mean frequency waveform of pulsed Doppler signal and the bandwidth of signal spectrum. Pulsed Doppler signals of normal flow and abnormal flow can be generated according to this model, which makes it easier to analyse the turbulence and vortex of flow from its pulsed Doppler signal.
出处 《复旦学报(自然科学版)》 CAS CSCD 北大核心 1995年第3期241-246,共6页 Journal of Fudan University:Natural Science
基金 英国SERC基金
关键词 脉冲多普勒 超声多普勒 计算机模拟 血流 检测 ultrasound pulsed Doppler, simulation
  • 相关文献

参考文献2

二级参考文献2

共引文献2

同被引文献24

  • 1EVANS D H, MCDICKEN W N. Doppler ultrasound: physics, instrumentation and signal processing [ M ]. Chichester : Wiley,2000.
  • 2HOI Y M,WOODWARD S H,KIM M. Validation of CFD simulations of cerebral aneurysms with implication of ge- ometric variations [ J ]. Journal of Biomechanical Engi- neering,2006,128 (12) :843-851.
  • 3MO Y L, COBBOLD S C. A nonstationary signal simula- tion model for continuous wave and pulsed doppler ultra- sound[J]. IEEE Transactions on Ultrasonics, Ferroelec- trics, and Frequency Control, 1989,36 (5) :522-530.
  • 4WANG Y, FISH P J. Arterial doppler signal simulation by time domain processing[ J]. European Journal of Ul- trasound ~ 1996,3 ( 3 ) :71-81.
  • 5JENSEN J. Estimation of blood velocities using ultra- sound :A signal processing approach [ M ]. New York : Cambridge University Press, 1996.
  • 6JENSEN J, MUNK P. Computer phantoms for simulating ultrasound b - mode and cfm images [ C ]//23rd Acous- tical Imaging Symposium, Boston, Massachusetts, 1997 : 75-80.
  • 7FANG X, WANG Y, WANG W Q. Doppler ultrasound signals simulation from vessels with various stenosis de- grees [ J ]. Ultrasonics ,2006,44 ( S1 ) : 173-177.
  • 8WANG L,ZHANG Y,WANG D,et al. A simulation model for doppler ultrasound signals from pulsatile blood flow in stenosed vessels [ C ]//International Conference on BioMedical Engineering and Informatics,2008:339-343.
  • 9SANKAR D S, HEMALATHA K. Pulsatile flow of Her- schel - Bulkley fluid through stenosed arteries--A mathematical model [ J ]. International Journal of Non - linear Mechanics ,2006,41 ( 8 ) :979-990.
  • 10OUNG H, FORSBERG F. Doppler ultrasound simulation model for pulsatile flow with nonaxial components [ J ]. Ultrasonic Imaging, 1996,18 (8) : 157-172.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部