摘要
本文在分析了室内住宅和室外市政给水管道流量计算公式的基础上,按住宅小区的特卢、和性质,提出了住宅小区给水管道流量的计算公式:q_g=AβN^(1/2)+BβN.对于任意一个住宅小区,公式计算的流量,既可与室内住宅也可与室外市政给水管道衔接,两衔接点不存在误差.
On the basis of comparison of calculation formulae to determine the designed flowrate of both indoor and municipal water supply pipelines a formula in form of qg = AβN+BβN to determine the deigned flowrate of water supply pipeline of residential quarter is proposed. For any residential quarter the calculated flowrate by this formula will be compatible with both indoor and outdoor pipelines without any error.
出处
《给水排水》
CSCD
1995年第2期28-30,共3页
Water & Wastewater Engineering