摘要 拉大间隙装静子对转子试验性能的影响段连丰,魏玉冰(中国航空工业总公司第606研究所沈阳110015)关键词压气机,试验1试验压气机试验件为进口叶尖相对马赫数MW1大于1.3的跨音速单级轴流压气机。其流道形状如图1。由图1可见,装静子与不装静子两种试验... The paper presents a test performance comparison of a transonic compressor rotor with and without stator installed. the results show that the radial distribution of the pressure in the rotor was varied, because a variation of a flow-path behind the rotor with the stator.Although the law of similitude in rotor inlet with and without stator was complied, but the radial distribution of a static pressure ratio in inlet/outlet of rotor was changed. In the consequence the overall performance and blad-element performance were varied, too. The line of the rotor performance with stator moved right-upward and the efficiency envelope moved upward. Therefore, the rotor performance determined ill the compressor stage test should be regarded as the basis in the evaluation of the rotor performance of axial-flow compressor stage.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 1995年第4期436-439,共4页 Journal of Engineering Thermophysics
关键词 间隙 压气机 试验 静子 转子 性能 影响 compressor test