摘要 研究辐射加热腔诊断孔堵口现象。实验采用波长为1.053μm、能量为300~400J、脉宽为~800ps的高斯型激光脉冲,双束对打具有双源区的腔靶。在激光入射口及内爆腔诊断口用两台亚千电子伏特X射线能谱仪监测源区与内爆区发射的X光谱。定性分析和讨论了堵口现象。 The study on pinhole closure of diagnostic pinhole in the cavity heated by radiation is reported. Laser Wavelength of 1. 053 μm, energy 300-400 J, pulse width -800 ps with Gaussian shape are used in the experiments. Two laser beams drive the Cavity target with two source regions. The sub-keV X-ray spectrum from source region and implosion region were measured by two sub-- keV X- ray energy spectrometers respectively through laser incidence hole and diagnostic hole. The pinhole closure problom was qualitatively analysed and discussed.
出处 《光学学报》 EI CAS CSCD 北大核心 1995年第12期1651-1656,共6页 Acta Optica Sinica
关键词 腔靶 诊断口 堵口 惯性约束聚变 cavity target, diagnostic hole, pinhole closure.