氧瓶燃烧-离子选择电极快速测定人发中的氟 被引量:3

Quick Determination of Fluoride in Human Hair with Oxygen-flask Combustion and Ion-Selective Electrode
下载PDF
导出
摘要 介绍一种用氧瓶燃烧-离子选择电极快速测定人发中氟含量的新方法.在选定的实验条件下,氟离子的线性范围为1.0×10^(-6)~1.0×10^(-2)mol/L.用于人发氟的分析,其相对标准偏差和回收率分别为3.7%(n=6)和100.7±11.8%((?)±s,n=5).此法比目前常用的分析方法更简便快速,可用于氟营养及氟中毒指标的检测. This paper describes a new method for quick measurement of the content of fluoride in human hair with oxygen-flask combustion and ion-selective electrode. Under the experimental conditions specified, the calibration cure for F is linear in the concentration range from 1.0×10-2~1.0×10-6mol/L. The relative standard deviation and the recovery in analysing fluoride in hairs were 3.7%(n=6)and 100. 7×11.8% (±s,n = 5)respectively. The method is simpler and quicker than common analytical method at present,and can be widely used in the measurement of trace targets in nutrition and poisoning of fluoride.
出处 《海军医高专学报》 1995年第2期91-93,共3页
关键词 人发 离子选择电极 氧瓶燃烧 毛发检验 fluoride human hair ion-selective electrode oxygen-flask combustion