期刊文献+

3D-PDA测量2相流场时散射粒子的选择 被引量:2

Selection of Scattering Particles When Measuring Two-Phase Flow with 3D-PDA
下载PDF
导出
摘要 应用激光技术测量流体速度时,需要合适的散射粒子。本文研究了激光三维粒子动态分析仪(3D-PDA)测量2相流场速度时,如何选择合适散射粒子的问题。研究结果表明,散射粒子的合理选择是保证测量精度的重要措施之一;测量湍流脉动较强流场时,应选用密度小、直径小、折射率大的粒子作散射粒子,并选择合适的粒子散播浓度。 The technigue of Laser Doppler velocity measurement in two phase fluid depends on sui-table particles. How to select the scattering particles in two-phase flow measurement with 3-Dimentional Particle Dynamic Analyzer (3D-PDA)is discussed in this paper. The results show that the property of scat-tering particles is a main factor affecting the velocity measurement, and those particles with smaller size,lower density and higher refractive index are highly suggested for the seeding in turbulent flow measure-ments.
作者 郭嘉 罗晔
机构地区 华中理工大学
出处 《航空计测技术》 1995年第1期10-11,28,共3页 Aviation Metrology & Measurement Technology
关键词 流体速度测量 2相流场 速度测量 散射粒子 3D-PDA, Two-phase flow, Velocity measurement, Scattering particle selection
  • 相关文献