期刊文献+

用Charpy试样研究核压力容器钢的韧性转变温度曲线 被引量:1

Studying of Toughness Transition Temperature Curve of Nuclear Pressure Vessel Steel by Use of Charpy Specimen
下载PDF
导出
摘要 用一个标准Charpy试样及试验过的该试样的两个半截试样所获得的8个“再造Charpy复合试样”评定核压力容器用A508CL3钢冲击韧性或断裂韧性的温度转变曲线。研究结果表明,用这种方法可得到一条较为可靠而完整的核压力容器钢的冲击韧性或断裂韧性随温度的转变曲线。这相当于在核监测计划中,只需取出一个Charpy试样即可得到完整的材料性能曲线,这对于提高核压力容器中子辐照脆化监测的可靠性很有价值,特别是对于运行时间较长(堆芯内监测试样数量已经不多)的核容器寿命预测和安全监视尤为重要。 This paper has investigated how to evaluate the dependence curves of impact toughness orfracture toughness vs temperature on nuclear pressure vessel A508CL3 steels by use of standardCharpy-size specimen and the eight reconstituted Charpy-size specimens which were manufactured from the two broken halves of the tested standard Charpy-size specimen. The researchresults indicate that a reliable and complete dependence curve of impact toughness or fracturetoughness vs temperature can be obtained by means of only one standard Charpy-size specimenand the eight reconstituted Charpy-size comPOund specimens which were manufactured from theformer. This is very valuable for improving the reliability of surveillance on nuclear pressurevessel embrittlement due to neutron iradiation. Especially, this method is extremely importantfor the life-time prediction and safety surveillance of a nuclear pressure vessel which has operated for a long-time and where there has been a few surveillance specimens remained.
机构地区 西安交通大学
出处 《核动力工程》 EI CAS CSCD 北大核心 1995年第2期166-170,共5页 Nuclear Power Engineering
基金 国家核安全局的资助
关键词 核压力容器 冲击韧性 断裂韧性 温度曲线 Nuclear pressure vessel Reconstituted Charpy compound specimen Impacttoughness Fracture toughness Temperature transition curve
  • 相关文献

参考文献2

二级参考文献4

  • 1A. A. Willoughby. Discussion: “A simple test method for measuring ‘valid’ JIC fracture toughness in Charpy-size surveillance specimens of nuclear pressure vessel steel,” by R. O. Ritchie et al.[J] 1979,International Journal of Fracture(3):R125~R126
  • 2R. O. Ritchie,W. L. Server,R. A. Wullaert. A simple test method for measuring “valid” JIc fracture toughness in Charpy-size surveillance specimens of nuclear pressure vessel steel[J] 1978,International Journal of Fracture(6):R329~R334
  • 3R. O. Ritchie,W. L. Server,R. A. Wullaert. A simple test method for measuring “valid” JIc fracture toughness in Charpy-size surveillance specimens of nuclear pressure vessel steel[J] 1978,International Journal of Fracture(6):R329~R334
  • 4张新平,史耀武.提高核压力容器中子辐射脆化断裂韧性监测可靠性的新方法[J].核动力工程,1992,13(5):76-82. 被引量:4

共引文献4

同被引文献2

引证文献1

二级引证文献2