期刊文献+

大亚湾核电站5.25停机事件的原因分析及解决办法

Cause Analysis and Solution for the Event Happened on May 25, 1994 in Daya Bay NPP
下载PDF
导出
摘要 确保核安全是核电站所有控制和保护系统设计的目的,与此相关的一些课题是我国核电设计、运行及电网控制的重要技术问题.为此对大亚湾核电站5.25事件的原因分析和解决办法作了较详细的论述,并对系统设计运行原理、优劣、对策等也进行了较详细的探讨. The aim of design on control and protection systems is to ensure the nuclear safety. The relevant subjects are still the important technical research topics on nuclear POwer plant design, operating and electric grid control in China. This paper describes in detail the causes and sloutions of the unit trip event happened on May 25, 1994. The principles, advantages and disadvantages, and proposals on system design and operation are also studied and described.
作者 郭宗林
机构地区 大亚湾核电站
出处 《核动力工程》 EI CAS CSCD 北大核心 1995年第5期436-442,共7页 Nuclear Power Engineering
关键词 核电站 停机事件 不停堆预期瞬态 周期试验 Daya Bay Nuclear power station The unit trip event Anticipated transient without trip On-Iine periodic test Load decrease at low frequency