摘要
确保核安全是核电站所有控制和保护系统设计的目的,与此相关的一些课题是我国核电设计、运行及电网控制的重要技术问题.为此对大亚湾核电站5.25事件的原因分析和解决办法作了较详细的论述,并对系统设计运行原理、优劣、对策等也进行了较详细的探讨.
The aim of design on control and protection systems is to ensure the nuclear safety. The relevant subjects are still the important technical research topics on nuclear POwer plant design, operating and electric grid control in China. This paper describes in detail the causes and sloutions of the unit trip event happened on May 25, 1994. The principles, advantages and disadvantages, and proposals on system design and operation are also studied and described.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1995年第5期436-442,共7页
Nuclear Power Engineering
关键词
核电站
停机事件
不停堆预期瞬态
周期试验
Daya Bay Nuclear power station
The unit trip event
Anticipated transient without trip On-Iine periodic test
Load decrease at low frequency