期刊文献+

用自射线照相技术研究放射性核素在岩石和矿物上的吸附 被引量:1

APPLICATION OF AUTORADIOGRAPHY TO SORPTION STUDIES OF RADIONUCLIDES OF ROCD AND MINERALS
下载PDF
导出
摘要 应用自射线照相和岩相照相技术联合图象法研究了锕系元素和长寿命裂变产物在岩石和矿物上的吸附行为,直接观察到不同矿物和化学成份对核素的吸附。应用这个方法,研究了 ̄(239)pu、 ̄(241)Am在花岗岩上的吸附, ̄(99)Tc在辉锑矿、锑赭石和脆硫锑铅矿上的吸附以及 ̄(125)I在灰硒汞矿上的吸附,得到了一些有价值的结果。 The sorption behaviors of actinides and long lived fission products on rock and minerals arestudied by a micrographic method based on autoradiograpy techneque. The method offers a possi-bility to observe directly the contribution of different minerals or chemical compositions to thesorption of the nuclides,The soption of on granite,the sorption of on stibnite,antimony ochre and jamesonite and sorption of on tiemannite are studied.
出处 《核化学与放射化学》 CAS CSCD 北大核心 1995年第2期117-121,共5页 Journal of Nuclear and Radiochemistry
关键词 自射线照相 锕系元素 裂变 吸附 岩石 矿物 Autoradiography Actinide Fission product Sorption Rock Mineral
  • 相关文献

同被引文献14

  • 1刘美玲,石心泉,周万灏,刘洪文,李东,贾孟春.人骨髓基质细胞向成骨细胞分化过程中差异表达基因的筛选[J].生理学报,2006,58(4):370-376. 被引量:1
  • 2C.克勒尔著.朱永贝睿,焦荣洲,徐景明,等,译.放射化学基础[M].北京:原子能出版社,1993:102.
  • 3Kanekal S,Sahai A,Jones R F,et al.Storage-Phosphor Autoradiography:A Rapid and Highly Sensitive Method for Spatial Imaging and Quantitation of Radioisotopes[J].J Pharmacol Toxicol Methods,1995,33:171-178.
  • 4Walker C,Walton C E,Fraser J M,et al.Dissection Autoradiography:A Screening Technique Using Storage Phosphor Autoradiography to Detect the Biodistribution of Radiolabelled Compounds[J].J Pharmacol Toxicol Methods,2001,45:241-246.
  • 5Ito T,Suzuki T,Lim D K,et al.A Novel Quantitative Receptor Autoradiography and in Situ Hybridization Histochemistry Technique Using Storage Phosphor Screen Imaging[J].J Neurosci Methods,1995,59:265-271.
  • 6Zeissler C J.Comparison of Semiconductor PixelArray,Phosphor Plate,and Track-Etch Detectors for Alpha Autoradiography[J].Nucl Instrum Methods Phys Res A,1997,392:249-253.
  • 7Cole J M,Nienstedt J,Spataro G,et al.Phosphor Imaging as a Tool for in Situ Mapping of ppm Levels of Uranium and Thorium in Rocks and Minerals[J].Chem Geol,2003,193:127-136.
  • 8Johansson L,Altzitzoglou T,Sibbens G,et al.Standardisation of 238Pu Using Four Methods of Measurement[J].Nucl Instrum Methods Phys Res A,2003,505:699-706.
  • 9Kienzler B,Rmer J,Schild D,et al.Sorption of Actinides Onto Granite and Altered Material From Aspo HRL[C].Mat Res Soc Symp Proc,2004,807:665-670.
  • 10蒋和兴.辐射测量中的立体角修正.原子能科学技术,1987,21(3):285-290.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部