摘要
用乳胶囊制成脑积水和脑室囊虫病的模型,行Isovist造影CT扫描。结果:造影剂浓度(V/V)0.5%~1%时,CT值65.1~128.3Hu,造影效果良好,浓度过小,对比度不足,效果不佳,浓度过高,将有较多伪影,可淹没或掩盖病变。以0.5%~1%Isovist脑室造影CT扫描44例,43例得到明确诊断,造影效果良好,其中交通性脑积水2例,室间孔粘连1例,导水管狭窄2例,正中孔粘连5例,脑室囊虫病33例,经手术和病理证实诊断符合率为100%。1例注入造影剂后距扫描时间过短,造影剂尚未扩散到病变部位而失败。
Model of hydrocephalus and ventricular cysticercosis were made by emulsion cyst was scaned using Isovist CT-ventriculography scanning. Result:When concentration of contrast medium was 0.5%~1%,CT volum was 65.1~128.3Hu,the effect of CT- ventricu- lography was best.As concentration was much higher,it produced false image and the focus was covered.44 patients were undergone Isovist CT- ventriculography.43 cases were definite diagnosis. Of them 2 cases with communicating hydrocephalus,1 case with foramen interven-triculare adhesion,2 cases with midbrain catheter stenosis,5 cases with median foramen of 4th ventricle adhesion,33 cases with cysticercosis. The rate of correct diagnosis was 100%.It was confirmed by operation and pathology.One patient had a fail CT- ventriculography,be-cause the interval time was short from the contrast medium emptied into lateral ventricle to CT scanning,and contrast medium had not diffused to the location of focus.
出处
《河南医学研究》
CAS
1995年第3期240-243,共4页
Henan Medical Research