蒸馏塔板上气、液两相流局部气含率的测定对于研究塔板上流体的流动状态、塔板清液层高度、两相传质性能和设备优化设计等具有重要意义。过去,测量塔板上气液两相流的气含率主要采用γ射线吸收法。该法能检测总体的气含率,但无法测局部气含率,且使用复杂。热膜风速仪是检测气、液两相流速度和气含率的先进仪器,本文采用先进的智能热膜风速仪(IFA-100),并配以微机采样系统,用于测量大型塔板上两相流的局部气含率。
Local gas-holdup in vapor - liquid two phase flow was measured by constant temperature anemometer (CTA) on a sieve tray with a micro-computer for data acquisition. Local gas holdup were obtained at different points and different liquid heights on the tray under various liquid and gas flow rates.
出处
《化工学报》
EI
CAS
CSCD
北大核心
1995年第5期621-624,共4页
CIESC Journal
基金
国家自然科学基金
和精馏分离重点实验室资助
关键词
热膜风速仪
气液两相流
气含率
塔板
蒸馏塔
hot - film anemometer, vayor - liquid two phase flow, gas holdup