期刊文献+

基于模态空间H_2范数的压电柔性梁结构动力学模型降阶 被引量:2

Model Reduction of Flexible Structures Using Spatial H_2 Norm of Modes
下载PDF
导出
摘要 利用模态的空间H2范数作为各个模态对多输入-无限维空间分布输出的压电柔性梁结构动力响应贡献大小的度量,并给出了一种根据各个模态对结构动力响应的贡献大小,对带有多个压电作动器块、输出为空间分布的柔性结构进行模态挑选而获得降阶模型的方法。最后以柔性简支梁结构为例给出了仿真结果,并与常规的模态截断方法进行了比较。 In flexible structures with multi-input and spatially distributed output, the contribution of modes to the dynamic response of system may change with the location of piezoelectric actuator patches. The paper presents the procedure of model truncation for piezoelectric flexible structures with actuator patches and spatially distributed output by using the spatial norms of modes serving as a measure of the intensity of modes to system response. Simulation result is given for comparison with other truncation techniques.
出处 《机械科学与技术》 CSCD 北大核心 2005年第8期960-962,998,共4页 Mechanical Science and Technology for Aerospace Engineering
基金 陕西省自然科学基金项目(D7010418)资助
关键词 模型降阶 模态截断 模态的空间范数 压电柔性梁结构 Model reduction Spatial norms of modes Flexible structures
  • 相关文献

参考文献5

  • 1Gawronski W. Balanced Control of Flexible Structures[M]. Springer, 1996.
  • 2Preument A, Elliot S J, Gardonia P. Responsive system for active vibration control[A]. Proceeding of the NATO Advanced Study Institute[C], 2002.
  • 3Moheimani S O R, Fu M. Spatial H2 norms of flexible structures and its application in model order selection[A]. Proceedings of the 37th Conference on Decision and Control[C], 1998,3623~3624.
  • 4Aldrihem O J. Optimal size and location of piezoelectric actuator/sensors: practical consideration[J]. Journal of Guidance, Control and Dynamics, 2000,23(3):509~515.
  • 5Moheimani S O R. Minimizing the out-of bandwidth dynamics in the model of reverberant system that arises in the modal analysis: implication on spatial H∞ control[J]. Automatica, 2000,36:1023~1033

同被引文献19

  • 1丁文镜.振动主动控制当前的主要研究课题[J].力学进展,1994,24(2):173-180. 被引量:30
  • 2连业达,张洵安,毕金凤,王朝霞.地震作用下新结构体系中阻尼器研究[J].工业建筑,2006,36(2):16-19. 被引量:21
  • 3郑骥,赵东东,张京军.ANSYS在压电智能板振动主动控制中的应用[J].河北建筑科技学院学报,2006,23(2):14-16. 被引量:6
  • 4Housner G W , et al. Structural control: past, present, and future[J]. Journal of Engineering Mechanics, 1997,(9)
  • 5Winson C, Feng M Q. Vibration control of super tall buildings subjected to wind loads[J]. International Journal of Nonlinear Mechanics, 1997,32(4) :657 -668
  • 6Feng M Q, Akim M. Vibration control of tall buildings using mega-sub configuration[ J ]. Journal of Engineertng Mechanics, 1995,121 (10) :1082 - 1087
  • 7Zhang X A, et al. Controlling characteristic passive mega-sub controlled frame subjected to random wind loads[ J]. Journal of Engineering Mechanics, 2005,131(10) :1046 -1055
  • 8Muscollno G. Dynamic response of multiply connected primarysecondary systems [ J ]. Earthquake Engineering and Structure Dynamics, 1990,(19) :205 -216
  • 9Zhou C H, Lai Z H. Suppression of nonlinear panel flutter with piezoelectric actuators using finite element method [J]. AIAA Journal, 1995, 33(6): 1098-1105.
  • 10Nam C H, Kim Y. Optimal design of composite lifting surface for flutter suppression with piezoelectric actuators [J]. AIAA Journal, 1996, 33(10): 1897-1904.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部