期刊文献+

牙种植体稳定性的评价方法 被引量:1

下载PDF
导出
摘要 牙种植体稳定性是判断种植体是否成功的重要参数之一,在选择牙种植体负载时机、判断骨结合界面的转归等方面具有重要意义。本文对常用的五种牙种植体稳定性评价方法的基本原理、临床应用、优缺点等做了综述。
作者 汪昆 李德华
出处 《中国口腔种植学杂志》 2005年第2期99-102,共4页 Chinese Journal of Oral Implantology
  • 相关文献

参考文献25

  • 1Szmukler - Moncler S, Piattelli A, Favero GA, et al.Considerations preliminary to the application of early and immediate loading protocols in dental implantology [J]. Clin Oral Implants Res, 2000, 11(1):12~ 25.
  • 2Gapski R, Wang HL, Mascarenhas P, et al. Critical review of immediate implant loading[J] . Clin Oral Implants Res, 2003 , 14(5):515~527.
  • 3Cameron HU, Pilliar RM, MacNab I. The effect of movement on the bonding of porous metal to bone[J]. J Biomed Mater Res, 1973 , 7(4) :301~311.
  • 4Hammerle CH, Glauser R. Clinical evaluation of dental implant treatment[J]. Periodontol 2000, 2004, 34:230~239.
  • 5Barewal RM, Oates TW, Meredith N, et al. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid - etched surface [J].Int J Oral Maxillofac Implants 2003, 18 (5): 641~651.
  • 6Andreas Beer ,Andre' Gahleitner ,Anders Holm, et al.Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible[J]. Clin Oral Implants Res, 2003, 14:616~620.
  • 7Tricio J, van Steenberghe D, Rosenberg D, et al. Implant stability related to insertion torque force and bone density: An in vitro study[J]. J Prosthet Dent, 1995,74(6):608~612.
  • 8Aparicio C, Rangert B, Sennerby L. Immediate/early loading of dental implants: a report from the Sociedad Espanola de Implantes World Congress consensus meeting in Barcelona, Spain, 2002[J] .Clin Implant Dent Relat Res, 2003,5 (1):57~60.
  • 9Buser D, Nydegger T, Oxland T, et al. Interface shear strength of titanium implants with a sandblasted and acid- etched surface: a biomechanical study in the maxilla of miniature pigs[J]. J Biomed Mater Res, 1999,45(2) :75~83.
  • 10Dehua Li, Stephen J. Ferguson, Thomas Beutler.Biomechanical comparison of the sandblasted and acid - etched and the machined and acid - etched titanium surface for dental implants[J]. J Biomed Mater Res ,2002,60:325~332.

同被引文献13

  • 1时宏富,蔡贤华,汪国栋,王华松,陈庄洪.股骨髁冠状面骨折的分型与治疗[J].中华创伤骨科杂志,2007,9(2):118-121. 被引量:24
  • 2谭军,王鸣鹏,万卫平,张国桢,贾连顺,赵定麟,屠开元.正常人腰椎椎体解剖结构的 QCT 研究及其生物力学意义[J].中国临床解剖学杂志,1997,15(1):59-63. 被引量:28
  • 3Hahn J. Clinical uses of osteotomes[J]. J Oral Implantol, 1999, 25 (1) : 23-29.
  • 4Tada S, Stegaroiu R, Kitamura E, et al. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis[J]. Int J Oral Maxillofac Implants, 2003, 18 (3) : 357-368.
  • 5Kohal R J, Weng D, Bachle M, et al. Loaded custom-made zirconia and titanium implants show similar osseointegration: An animal experiment[J]. J Periodontol, 2004, 75(9):1262-1268.
  • 6Salata LA, Burgos PM, Rasmusson L, et al. Osseointegration of oxidized and turned implants in circumferential bone defects with and without adjunctive therapies: An experimental study on BMP-2 and autogenous bone graft in the dog mandible[J]. Int J Oral Maxillofac Surg, 2007, 36 (1) : 62-71.
  • 7Botticelli D, Berglundh T, Persson LG, et al. Bone regeneration at implants with turned or rough surfaces in self-contained defects. An experimental study in the dog[J]. J Clin Periodontol, 2005, 32(5) :448-455.
  • 8Demirel M, Dereboy F, Ozturk A, et al. Arthroscopically assisted intra-articular lateral femoral condyle fracture surgery[J]. Arthroscopy, 2006, 22 (6) : 690.
  • 9Hak DJ, Nguyen J, Curtiss S, et al. Coronal fractures of the distal femoral condyle: A biomechanical evaluation of four internal fixation constructs[J]. Injury, 2005, 36(9):1103-1106.
  • 10Dalle Carbonare L, Bertoldo F, Valenti MT, et al. Histomorphometric analysis of glucocorticoid-induced osteoporosis[J]. Micron, 2005, 36 (7/8) : 645-652.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部