期刊文献+

三峡永久船闸人字门背拉杆预应力调试计算 被引量:10

Calculation for Adjustment of Diagonal Prestress of Miter Gate in Three Georges Project Permanent Lock
下载PDF
导出
摘要 三峡永久船闸人字闸门通过设置背拉杆并对其施加一定大小的预应力来提高门体的抗扭性能。按三维有限元计算了单项荷载作用下人字门的应力与位移,建立了14根背拉杆预应力优化模型和简化的4根背拉杆预应力优化模型。根据优化模型得到预应力调试规律:①上层杆受拉,对上层杆应力影响大,对下层杆应力的影响量几乎可以忽略不计;反之,下层杆受拉,对下层杆应力影响大,对上层杆应力的影响量几乎可以忽略不计。②上主杆应力同时达到σ=1MPa,上副杆自动产生拉力σ=0.7MPa;下主杆应力同时达到σ=1MPa,下副杆自动产生拉力σ=0.5MPa。通过计算优化模型还确定了几组背拉杆预应力值,可供施加预应力值时参考。 By setting up diagonals applied with prestress, the miter gate in Three Georges Project permanent lock can raise the torsion rigidity. Based on three dimensional finite element method, the stresses and displacements of the miter gate applied by every single load are calculated. The 14-bar optimization model and a simplified 4-bar optimization model for calculating the diagonal prestress are established. It is deduced from the optimization models: ① When one upper diagonal is tensioned, only the stresses of the upper diagonals are changed, and those of the lower diagonals not changed almost; When one lower diagonal is tensioned , only the stresses of the lower diagonals are changed, and those of the upper diagonals not changed almost. ② As the stresses of the upper primary diagonals σ = 1 MPa simultaneously, then the stresses of the upper secondary diagonals σ =0. 7 MPa; As the stresses of the lower primary diagonals σ = 1 MPa simultaneously, then the stresses of the lower secondary diagonals σ = 0. 5 MPa. Some groups of prestress are calculated, it can be used for the adjustment of the diagonal prestress.
出处 《长江科学院院报》 CSCD 北大核心 2005年第4期72-75,共4页 Journal of Changjiang River Scientific Research Institute
关键词 人字门 背拉杆 预应力 优化 调试 miter gate diagonal prestress optimization adjustment
  • 相关文献

参考文献3

二级参考文献1

  • 1史述昭 谭道宏.船闸人字门斜杆预应力优化方案[J].武汉水利电力学院学报,1989,(3):1-7.

共引文献13

同被引文献32

引证文献10

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部