期刊文献+

Preparation of Nanosized CoHCF Modified Electrode and Its Application to Electroanalysis of Hemoglobin 被引量:2

Preparation of Nanosized CoHCF Modified Electrode and Its Application to Electroanalysis of Hemoglobin
原文传递
导出
摘要 A cobalt hexacyanoferrate (CoHCF) nanoparticle (size ca. 60 nm) chemically modified electrode (CME) was fabricated and the electrochemical behavior of hemoglobin (Hb) at this nanosized CoHCF CME was studied. In comparison with a bare glassy carbon electrode (GCE) and a general CoHCF CME electrodeposited in a traditional manner, the present nanosized CoHCF CME performed efficiently electrocatalytic reduction for Hb with relatively high sensitivity, stability, and longlife, Combined with liquid chromatography (LC), the nanosized CoHCF CME was used as the electrochemical detector of Hb in the established flow injection analysis-electrochemical determination (FIA-ECD) system. The peak current was a linear function of concentrations in the range from 2.5×10^-8 to 5.0×10^-6mol/L for Hb, with detection limit of 1.4×10^-8 mol/L. The FIA-ECD system has been successfully applied to assess the Hb content of clinic blood samples with advantages of sensitiveness, speediness, easy control and small sample-consumption. A cobalt hexacyanoferrate (CoHCF) nanoparticle (size ca. 60 nm) chemically modified electrode (CME) was fabricated and the electrochemical behavior of hemoglobin (Hb) at this nanosized CoHCF CME was studied. In comparison with a bare glassy carbon electrode (GCE) and a general CoHCF CME electrodeposited in a traditional manner, the present nanosized CoHCF CME performed efficiently electrocatalytic reduction for Hb with relatively high sensitivity, stability, and longlife, Combined with liquid chromatography (LC), the nanosized CoHCF CME was used as the electrochemical detector of Hb in the established flow injection analysis-electrochemical determination (FIA-ECD) system. The peak current was a linear function of concentrations in the range from 2.5×10^-8 to 5.0×10^-6mol/L for Hb, with detection limit of 1.4×10^-8 mol/L. The FIA-ECD system has been successfully applied to assess the Hb content of clinic blood samples with advantages of sensitiveness, speediness, easy control and small sample-consumption.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2005年第8期983-989,共7页 中国化学(英文版)
基金 Project supported by the National Natural Science Foundation of C'hina(No. 20305007), Doctoral Foundation of China University of Ministry of Education (No. 20030269014) and Shanghai Rising-Star Program (No. 04QMX 1421).
关键词 nanosized cobalt hexacyanoferrate chemically modified electrode HEMOGLOBIN direct electrochemical determination flow injection analysis-electrochemical determination clinic blood nanosized cobalt hexacyanoferrate chemically modified electrode, hemoglobin, direct electrochemical determination, flow injection analysis-electrochemical determination, clinic blood
  • 相关文献

同被引文献36

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部