期刊文献+

动脉功能检测方法学研究 被引量:23

Study of artery function evaluation methods
下载PDF
导出
摘要 目的:探讨无创检测动脉功能和结构的方法脉搏波速度测定和超声技术的重复性及可靠性。方法:选取10名健康受试者,年龄21-35岁,平均(24.6±5.5)岁,在间隔24小时内分别进行PWV测定及超声颈动脉和肱动脉内径,内膜-中层厚度的测量,观察两次测量之间的改变情况。结果:两次测试比较,收缩压和心率无显著性改变均为P=NS。颈动脉-股动脉PWV:(7.53±0.66)m/s比(7.35±0.87)m/s,P=0.3547;超声测定的颈总动脉舒张末径:(6.07±0.56)mm比(6.17±0.58)mm,P=0.5278;颈总动脉内膜-中层厚度:(0.378±0.102)mm比(0.358±0.094)mm,P=0.3315;肱动脉舒张末径:(3.48±0.71)mm比(3.49±0.74)mm,P=0.8409;肱动脉内膜-中层厚度:(0.210±0.078)mm比(0.199±0.080)mm,P=0.2625。在两次测量之间均无显著性差异。结论:PWV和超声技术可以无创,方便地进行动脉结构和功能检测,具有良好的重复性,利用临床推广用于血管病变早期检测。 Objictive: To explore reproducibility and reliability ofnoninvasive artery structure and function evaluation methods pulse wave velocity(PWV) measurement and ultrasound. Methods: 10 cases healthy volunteers were examined. Mean age(21 -35 )(24.6 ±5.5 )years, PWV measurement carotid and brachial arterydimension and intima- media thickness were measured by ultrasouncl for two tiros at 24 hours interval. Change between twomeasurements were evaluated. Results: Compared two measurements,Systolic blood pressure and heart rate had no Significant change ( P = NS). Carotid - femoral PWV [ (7.53 ± 0.66 ) m/s 比 (7.35 ± 0.87 )m/s, P = 0.3547 ], Comon Carotid dimension [ (6.07 ± 0.56 ) mm 比 (6.17 ± 0.58 ) mm, P = 0. 5278 ], Carotid intima - media thickness[ (0. 378 ± 0. 102) mm 比 (0. 358 ±0. 094) mm,P = 0. 3315 ] ,brachial artery diastolic dimension[ (3.48 ± 0.71 ) mm 比 (3.49 ± 0.74 ) mm, P = 0.8409 ], brachial artery intima - media thickness [ (0.210 ± 0.078 ) mm 比 (0. 199 ± 0.080 ) mm, P = 0.2625 ] had no significautchange between two examinations. Conslusion: PWV and Ultrasound Could noninvasively and simply exam artery Structure and function,had good reproducibility, may be useful for early vascular disease detection.
出处 《中国民康医学》 2005年第8期420-421,共2页 Medical Journal of Chinese People’s Health
关键词 动脉 脉搏波速度 超声 Artery Pulse wave velocity Ultrasound
  • 相关文献

参考文献8

二级参考文献45

  • 1Chen C H,Circulation,1998年,97卷,422页
  • 2周永昌,超声医学(第3版),1998年,549页
  • 3Ludmer P L , Selwny A P , Shook T L , et al . Paradoxical vasoconstriction induced by acetylcholine in atherosclerotic coronary arteries . N Engl J Med. 1986,325(17): 1046-1051.
  • 4David S Celermajer et al . Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis . Lancet,1992,340 (8828) :1111-1115.
  • 5Anderson T J , Uehata A, Gerhard MD, et al. Close relation of endothelial function in the human coronary and peripheral circulationsJ Am Coll Cardiol 1995,26(5 ) :1235 -1241.
  • 6David S Celermajer. Testing endothelial function using ulthasound J Cardiovascular Pharmacology,1998, 32(3) :29 -32.
  • 7Sorensen K E , Celermajer D S , Spiegelhalter D J , et al. Noninvasive measurement of human endothelium dependent arterial responses accuracy and reproducibility. Br Heart J, 1995,74 ( 3 ):247-253.
  • 8Berry KL, Skyme-Jones RA, Meredith IT. Occlusion cuff position is an important determinant of the time course and magnitude of human brachial artery flow -mediated dilation. Clin Sci(Lond) ,2000,99(4): 261 -267.
  • 9Bressler B , Chan S , Mancini G B . Temporal response of brachial artery dilation after occlusion and nitroglycerin . Am J Cardiol,2000,85(3): 396 -400,A10.
  • 10Vogel R A, Correti M C , Plotnick G D. Effect of a single high fat meal on endothelial function in healthy subjects . Am J Cardiol,1997,79(3) : 350 -354.

共引文献391

同被引文献261

引证文献23

二级引证文献101

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部