摘要 V. EXPERIMENTAL RESULTS Fig. 13. Output current waveforms of the proposed system at steady state at(a) 20 Hz, (b)40 Hz, and (c)60 Hz(upper trace: LCI output current [1 A/div); middle trace: VSI output current(1 A/div); lowertrace: motor current(1 A/div)]. To validate the proposed topology and control algorithm, the prototype hybrid system was developed using an LCI, a phasecontrolled rectifier, and a VSI. An insulated- gate-bipolar-transistor (IGBT)-based commercial inverter (SEMIKRON) was used as a VSI. In addition, a prototype of a phase-controlled rectifier and an LCI was fabricated in the laboratory.