摘要
全数字化调控的,具有"热插拔"和现场"易增容"特性及智能化管理功能的模块化、阵列式UPS冗余并机电源可向信息网络提供具有高"可利用率"的电源。它主要为由工作站、网关、服务器等所组成的中、小型网络及与其配套的通信设备所设计,并可由"非专业人士"在用户现场就能组装成"N+X"型UPS冗余供电特性的UPS供电系统。同第1代模块化UPS电源相比,采用"分布式并机调控"设计方案制备的第2代模块化、阵列式UPS电源,不仅显著地提高了这种UPS的冗余并机系统的输出特性,消除"单点瓶颈故障"隐患。而且大大地增强了它对外接电池组的充电能力和电池组的充放电的管理功能。
The array type of modular UPS system can provide a high availability, easily scalable system to adapt to change IT by adding power and/or battery modules of “N+ 1”UPS for small and middle size of the network and the related equipment. It is characterized as the following technical advantages:the DSP control design, hot-swappable design of power and battery modules and intelligent management system. Especially,it can be assembled as a “N+X” parallel redundancy UPS at worksite by non-professional men. In order to eliminate single point of failure, the distributed parallel control, instead of centralized parallel control and an intelligent battery management system with powerful charger are applied to the itrust 2G series of UPS as compared with the first generation of modular UPS.
出处
《电源世界》
2005年第7期39-46,共8页
The World of Power Supply