期刊文献+

冠状动脉三维重建在冠心病的应用价值

MSCT scanning technology of coronary artery with 3D reformation
下载PDF
导出
摘要 目的:探讨多层螺旋CT(MSCT)在冠状动脉血管造影检查中最佳的扫描技术。方法:应用回顾性心电门控技术,使用3种不同的检查技术,对62例患者进行多层螺旋CT冠状动脉增强检查:15例使用对比剂注入后延时扫描无维持注射的方法;23例使用对比剂自动跟踪技术(surestart)自动控制扫描,对比剂一次性团注的方法;24例使用surestart技术手动控制扫描、CT实时监视技术,对比剂团注后+维持注射的方法。结果:15例使用对比剂注入后延时扫描无维持注射的方法进行的冠状动脉检查,9例成功占60%(9/15);23例使用surestart技术自动控制扫描,不使用维持量注射的方法进行冠状动脉检查,16例成功,占69.57%(16/23);24例使用surestart技术手动控制扫描、CT实时监视技术,对比剂团注后+维持注射的方法,进行冠状动脉检查,22例成功,占91.67%(22/24)。结论:Surestart技术手动控制扫描、CT实时监视技术,对比剂团注后+维持注射的方法,成功率较高。 Objective: To investigate MSCT scanning technology(Toshiba Aquilion M16 )in contrast enhancement study of coronary artery.Methods:62 patients underwem MSCT contrast enhancement examination of coronary artery applying three methods: 15 patients applied delay scanning without continuing injection after bolus contrast agent given; 23 patients applied surestart technique automatically tracking scanning after contrast agent bolus injection; 24 applied manual surestart technique under monitoring scanning with contrast agent remaining after bolus injection. Results: In group 1,9 of 15 patients (60%) showed satisfactory imaging quality. In group 2, 16 of 23 patients (69.57%) showed satisfactory imaging quality. In group 3, 22 of 24 patients (91.67%) showed satisfactory resuhs. Conclusion:The manual surestart technique under monitoring scanning with contrast agent remaining after bolus injection could be a satisfactory method in contrast enhancement scanning of coronary artery.
出处 《医学影像学杂志》 2005年第7期544-547,共4页 Journal of Medical Imaging
基金 福建省科技厅重点课题(02A020)
关键词 体层摄影术 X线计算机 冠状动脉 三维重建 Tomography, X-my computed Coronary artery 3-Dimention reformation
  • 相关文献

参考文献6

二级参考文献31

  • 1邵广瑞,柳澄,刘延军,王道萍.多层螺旋CT与选择性冠状动脉造影对照研究及其临床应用[J].中华放射学杂志,2003,37(9):805-808. 被引量:80
  • 2Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenoses by contrast - enhanced, retrospectively electrocardiographically - gated, multislice spiral computed tomography. Circulation 2001; 103:2535 ~ 2538
  • 3Nikolaou K, Huber A, Knez A, et al. Intraindividual comparison of contrast - enhanced electron - beam computed tomography and navigator - echo - based magnetic resonance imaging for noninvasive coronary artery angiography. Eur Radiol 2002; 12:1663 ~ 1671
  • 4Ropers D, Ulzheimer S, Wenkel E, et al. Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic - gated image reconstruction. Am J Cardiol 2001;88:792 ~ 795
  • 5Knez A, Becker C, Becker A, et al. Determination of coronary calcium with multi - slice spiral computed tomography: a comparative study with electron - beam CT. Int J Cardiovasc Imaging 2002; 18:295 - 303
  • 6Chernoff DM, Ritchie CJ, Higgins CB. Evaluation of electron beam CT coronary angiography in healthy subjects. Am J Roentgenol 1997; 169: 93- 99
  • 7Stuber M, Botnar RM, Danias PG, et al. Double - oblique free -breathing high resolution three - dimensional coronary magnetic resonance coronary angiography. J Am Coll Cardiol 1999; 34:524 - 531
  • 8Nieman K, Rensing BJ, van Geuns RJ, et al. Non - invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 2002; 88: 470 - 474
  • 9Hong C, Becker CR, Huber A, et al. ECG - gated reconstructed multi - detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 2001;220:712 - 717
  • 10Becker CR, Jakobs TF, Aydemir S, et al. Helical and single -slice conventional CT versus electron beam CT for the quantification of coronary artery calcification. A JR Am J Roentgenol 2000; 174:543 - 547