期刊文献+

家用除铁净水器的研制

STUDY ON DOMESTIC FILTER FOR REMOVING IRON IN DRINKING WATER
下载PDF
导出
摘要 家用除铁净水器有效高度为400mm,容积4.3L,每小时出水量30~40L,一步运行在除铁的同时还能除锰,解决了除铁装置不能除锰的难题。对pH值、溶解氧浓度、色度、水温等影响因素进行了试验。结果表明pH值在5.5以上,溶解氧浓度在2mg/L以上,色度在50°以下对除铁除锰效果无明显影响。经现场试用,原水舍铁量9mg/L可连续使用23h,5mg/L可连续使用53h,3mg/L可连续使300h,处理后水铁锰含量均符合国家饮用水卫生标准。 domestic filter for remoring iron and manganese simultaneously indrinking water was developed.It is 400mm high and 4.3L volume. Its rateof flow is 30~40L/h,The exoerimental results showed that it runs well underthe operation condition as following. pH value over 5.5,water temperatureover 5 ℃,concentrations of dissolved oxygen ovgen over 2mg/L,and colority be- neath 50 units in raw water.The factors mentioned above had no significanteffect on removing iron and manganese in raw water.By field test.it couldcontinuously treat the water containing iron 9mg/L for 23h,or 5mg/Lfor 53h,or 3mg/L for 300h.Iron and manganese concentrations in waterafter filtration met the national health standard of drinking water.
出处 《解放军预防医学杂志》 CAS 北大核心 1995年第1期22-26,共5页 Journal of Preventive Medicine of Chinese People's Liberation Army
关键词 家庭 饮用水 净水器 水处理设备 除铁 除锰 natural manganese sand,drinking water,removing lron,domestic filter