摘要 应用概率理论对高层建筑火灾时防烟楼梯间同时开启门数量的确定进行了分析。结果表明,高层建筑火灾时同时开门楼层数与建筑疏散人数、疏散出口数量、有效疏散时间、建筑物总层数、疏散出口宽度、疏散出口流动系数等因素有关,每个安全出口负担的疏散人员数是影响防烟楼梯间同时开门楼层数的关键因素,当每个安全出口负担的疏散人员数超过75人/层时,为了减少同时开门楼层数,应适当增加安全出口数量。 Analyses the simultancous opening door quantity in smoke-preventing stairwell with probability theory. The result shows that the simultaneous opening door quantity has correlation with evacuation occupant quantity, exit quantity, effective evacuation time, building total story number, exit door width and occupant's flow velocity at exit. Occupant quantity at each exit is a key issue, when the occupant quantity in one story exceeds 75, the safe exit quantity should be increased to decrease simultaneous opening door quantity.
机构地区 哈尔滨工业大学
出处 《暖通空调》 北大核心 2005年第8期86-90,共5页 Heating Ventilating & Air Conditioning
基金 哈尔滨工业大学跨学科交叉性研究基金资助项目(HIT.MD2001.33)
关键词 高层建筑 火灾 同时开启门数量 安全出口 疏散人员数量 概率 高层建筑火灾 开启 防烟楼梯间 疏散人数 high-rise building, fire, simultaneous opening door quantity, exit, evacuation occupant quantity, probability
  • 相关文献

参考文献3

  • 1GB50045-95.高层民用建筑设计防火规范.[S].,..
  • 2刘朝贤.防烟楼梯间及其前室加压防烟系统火灾疏散时开启门数量的探讨[A]..见:全国暖通空调制冷1998年学术年会论文集[C].,1998.117-120.
  • 3同济大学工程数学教研室.概率统计复习和解题指导[M].上海:同济大学出版社,2000..