期刊文献+

La传感器及其在碳饱和铁液与凝固中La活度的研究

PREPARATION OF La SENSOR AND DETERMINATION OF La ACTIVITY IN C-SATURATED MELTED IRON AND ITS SOLIDIFICATION PROCESS
下载PDF
导出
摘要 制得多晶La_(0.95)Ca_(0.05)F_(2.95)固体电解质管,以纯La作为参比电极,组成La传感器电池形式为:Mo|La(1)of(s)|La_(0.95)Ca_(0.05)F_(2.95)|[La]Fe|Mo金属陶瓷。于1573K测定了碳饱和铁液中不同La浓度下熔解态La的活度,与同时用氧传感器测得的氧的变化规律相符合追踪测定了1623K碳饱和铁液凝固过程中溶解态La活度随温度的变化,结果呈现规律性La传感探头在降温和升温过程中可连续使用。 The La sensor was composed of polycrystalline La0.95Ca0.05Fz.gs as solid electrolyte, pure La as reference electrode and Mo wire as lead wire. It can be expressed as:Mo|La(1)or (s) |La0.95 Ca0.05F2.95|[La]Fe Mo ceramal. The activity of dissolve La in C-saturated melted iron (1300℃) with different La concentration was detennined. The result was in agreement with that of O2 concentration cell e.m.f determined by O2 probe. The activity change of La with temperature in the solidified process (from 1350℃) was also determined and shows regularity. With the temperature changing from 1350℃ to 600℃, the activity of La varied from 10 ̄(-4) to 10 ̄(-20)
作者 王平 王常珍
机构地区 东北大学
出处 《金属学报》 SCIE EI CAS CSCD 北大核心 1995年第9期B394-B398,共5页 Acta Metallurgica Sinica
基金 国家自然科学基金
关键词 传感器 活度 碳饱和铁 凝固 sensor, activity, La, carbon saturated melted iron
  • 相关文献

参考文献2

  • 1邹开云,中国稀土学会第三届学术年会论文集,1994年
  • 2肖理生,金属学报,1993年,29卷,B335页

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部