本文通过比较分析,提出了一种新的测定铁离子浓度的容量分析方法。即以锌丝代替氯化亚锡,避免了使用剧毒的氯化汞,减少了对人体的危害和对环境的污染,而且提高了测定结果的准确度。
A new method for determining the concentration of ferric ion with capacity analysis has studied in the paper.In order to avoid using very poisonous mercury chloride zinc filament has used iusted of tin dickloride and pollution to environment are reduced and the accuracy of determining results is enhanced.
出处
《洛阳工学院学报》
1995年第3期88-91,共4页
Journal of Luoyang Institute of Technology
关键词
铁离子
浓度
电极电位
容量法
测定
Concentration of ferric ion Tin dichloride Zinc Electrode potential