摘要
本文提出了煤气热电联产系统的循环流化床锅炉容量与煤气产量需相互匹配的原则和计算方法,同时编制了制气煤干馏过程和循环流化床锅炉的容量确定的计算程序,通过计算考查了干馏温度和煤种对锅炉容量的影响,推荐了供生产实际选择煤气热电联产系统的生产规模系列。
The matching principle of a circulating fluidized bed boiler(CFBB) capacity and town gas output in the system of town gas-heat-power co-generation is put forward in this paper. The calculating program of the coal distillation and determination of the CFBB capacity are made,The effect of distillation temperatur and coal kind on the capacity of CFBB are discussed.The series of town gas-heat-power co-generation system are recommended.
出处
《煤气与热力》
北大核心
1995年第2期38-41,共4页
Gas & Heat
关键词
煤气
热电联产
锅炉
容量
煤气
匹配
gas-heat-power co-generation,capacity of boiler,output of town gas.