摘要
本文首次将可靠性分析技术——故障树分析,试用到电工产品,构造了一种110kV 以上电流互感器的故障树,进行了定性定量分析,并进行了论讨。用以开创高压电流互感器可靠性的研究,为高压电流互感器的可靠性设计、制造、试验与进行维护提供依据与参考。
In this paper the reliability technique is used for the electrical products and the Fault Tree of the current transformer operating at 110kVand above is built.The qu- alitative analysis,quantitative analysis and some discussions are represented.It is us- ed for developing the reliability study of the high voltage current transformer and supplying the basis and reference to the designer,manufacturer,tester and repairer.
出处
《电工技术学报》
EI
CSCD
北大核心
1989年第4期45-49,39,共6页
Transactions of China Electrotechnical Society
基金
"七五"国家重大技术装备科技攻关项目75-50-05-01-21E 专题论文之一。