期刊文献+

双馈同步感应发电机的运行性能分析 被引量:3

Analysis of the Doubly Fed Synchronous Induction Generator
下载PDF
导出
摘要 本文分析了自励和他励双馈同步感应发电机的运行性能。用综合矢量法推导出教学模型,并用绕线式异步电动机改制成定、转子绕组有效匝数接近相等的发电机模型机。利用数学模型计算了自励式的外特性、调整特性及三相突然短路电流,并对他励式进行稳定性分析。计算结果与模型机试验结果吻合较好。 This paper explores the performance of the self excited and external-excited doubly fed synchronous-induction generator.The mathematical model has been worked out and the proto-type machine has been built with the effective number of turns of the stator and rotor windings nearly equal to eliminate the circulating current,With the mathematical model,the external characteristic,regulation charact- eristic and sudden short-circuited current of the self excited machine are calculated and stability analysis of the external-excited machine is carried out.The computed results show good accordance with the test data of the proto-type machine.
机构地区 福州大学
出处 《电工技术学报》 EI CSCD 北大核心 1989年第4期29-33,共5页 Transactions of China Electrotechnical Society
  • 相关文献

参考文献3

  • 1邱培基,1987年全国电机学术年会论文集,1987年
  • 2卓忠疆,机电能量转换,1987年
  • 3牛维杨,太原工业大学学报,1985年,1期

同被引文献10

引证文献3

二级引证文献30