摘要
110例运动试验阳性的冠心病患者多导联监测结果表明:①运动后ST段压低的恢复时间在V3、V4最长,V6、Ⅲ导最短。两组比较差异显著(P<0.05),说明导联对ST段压低恢复时间的影响。②各导联ST段压低恢复时间的长短与ST段压低的深度、形态无关,而与ST段压低的出现时间有关。③Ⅱ、Ⅲ、avF、V3、V4、V5、及V6对ST段压低的检出率分别为50.9%、77.3%、63.6%、20.9%、54.5%、69.1%及68.2%。
he reuslts from multi-lead-monitoring in ll0 CHD
patients with positive exercisetesting showed :1. The longest
recovery time of ST depression was in leads V3and V4,while the
shortest recovery time of ST depression was in leads V6and III, the
difference be- tween the two groups was significant(P<0.05), which
indicated the influence of the leadson recovery time of ST
depression;2.Therecovery time of sT depression was not correlat-ed
with the occurrence time of ST depression;3.The detect able rate of
ST depression in leads II,III,avF,V3,V4,V5andV6was
53%,77%,64%,23%,56%,70%and 68% respectivelay.
关键词
冠心病
ST段
心电描记术
exercise
testing
coronary disease
recovery time of ST
depression
electrocar-diography