期刊文献+

指向性声源的自由空间有源消声 被引量:2

Active sound control by diectional secondary sources in the free field
下载PDF
导出
摘要 本文根据最小辐射声功率准则,推导了当初级源和次级源的声辐射均具有指向性时,次级源最优复强度的一般表达式.分析结果表明该式具有普遍性。文中最后讨论了几种典型和常见的声源结构有源消声的特点,给出了次级源最优复强度及消声前后辐射功率比的表达式。 In this paper, a general formula for caculating the complex strengths of secondary sources is derived according to the criterion of minimizing the total acoustic power output while both of primary and secondary sources are with difectivity. Analytic results show that the formula is of universal significance. In the last, the speCific properties are presented for some typical secondary sources commonly used in active sound control, and these results are shown in figures.
出处 《声学学报》 EI CSCD 北大核心 1995年第3期191-198,共8页 Acta Acustica
  • 相关文献

参考文献2

二级参考文献1

  • 1田静,沙家正.空间有源消声器研究[J]声学学报,1987(01).

共引文献1

同被引文献22

  • 1王冲,孙进才.分布声源的有源消声理论研究[J].振动工程学报,1993,6(2):118-124. 被引量:2
  • 2王冲,孙朝晖,孙进才.自适应空间有源消声中误差传声器的位置及个数优化[J].声学学报,1994,19(3):179-187. 被引量:8
  • 3侯宏,王冲,杨建华,孙进才.多声源的自由场有源声吸收[J].声学学报,1994,19(3):188-195. 被引量:3
  • 4Bolt Beranek. A method for predicting the audible noise emis sions from large outdoors power transformers[J]. IEEE Trans actions on Power Apparatus and Systems, 1979, 98( 3): 1109 1112.
  • 5Girgis R, Garner K, Bernesj6 M. Measuring no-load and load noise of power transformers using the sound pressure and sound intensity methods, part I outdoors measurements[C]. Power and Energy Society General Meeting-Conversion and Delivery of Electrical Energy in the 21st Century. Pittsburgh, PA, USA: Power and Energy Society, 2008: 1-8.
  • 6Cover W B, Ringlee R J. Recent contributions to transformer dible noise control[J]. Transactions of the American Institute of Electrical Engineers, Part Ⅲ Power Apparatus and Sys- tems, 1955, 74(3): 77-90.
  • 7Ross C F. Experiments on the active control of transformer noise[J]. Journal of Sound and Vibration, 1978, 61(4): 473 480.
  • 8Hesselmann N. Investigation of noise reduction on a 100 kVA transformer tank by means of active methods[J]. Applied A- coustics, 1978, 11(1): 27-34.
  • 9Berge T, Pettersen O Kr, Sorsdal S. Active canceUation of transformer noise: field measurements[J]. Applied Acoustics, 1988, 23(4): 309-320.
  • 10Bake K H, Elliott S J. Natural algorithms for choosing source locations in active control system[J]. Journal of Sound and Vi- bration, 1995, 186(2): 245-267.

引证文献2