期刊文献+

新型组合电收尘器的结构和机理

The Construction and Fundamentals of a New Type Combined Electrostatic Precipitator
下载PDF
导出
摘要 本文介绍了新型组合电收尘器的结构和机理。这种组合收尘器把电气收尘和机械收尘组合起来,进行电旋、电抑、电凝三级收尘,其实用的入口含尘浓度为176.24g/Nm^3,排放浓度为85.4mg/Nm^3,收尘效率为99.95%。 The construction and fundamentals of a new type combined electrostaticPrecipitutor (CEP) are discribed in this paper. CEP combines electrostaticprecipitation with mechanical collection, so that it incorporates the best fea-tures of the electro-cyclone, electro-inhibitor and electro-agglomerator. Theperformance parameters of CEP applied in industry are the inlet dust concen-tration 176.24g/Nm^3, the outlet content 85.4mg/Nm^3 and the collection effi-ciency 99.95%.
出处 《中国科学技术大学学报》 CAS CSCD 北大核心 1989年第1期99-104,共6页 JUSTC
关键词 电收尘器 电旋风 电抑制 电凝聚 electrostatiorc precipitator (EP) tubular EP's tubular EP's of two-stage electro-cyclone electro-inhibitor electrostatic agglomeration combined electrostatic precipitator
  • 相关文献

参考文献4

  • 1王成汉,工业电收尘,1984年
  • 2谭天--,电除尘器,1983年
  • 3大野长太朗,除尘、收尘理论与实践,1981年
  • 4陈明绍,除尘技术的基本理论与应用,1981年