摘要
采用组合式密封层和特制的引出导线密封装置,测定了在较高水压作用下的绕管式换热器的管板应力。测试结果表明,实验值与有限元计算值基本一致。
In the paper,the stresses in the tubesheet of wrapped-tube-exchangerwere measured using a combined sealed layer and a special manufactured out-wire sealedequipment under higher pressure water. The results show that the experimenetal dataare in agreement with the results of finite element method.
出处
《石油化工设备》
CAS
北大核心
1995年第1期31-33,共3页
Petro-Chemical Equipment