期刊文献+

两种不同固位体设计的可摘局部义齿对牙槽骨的应力研究 被引量:1

A Study of Stress on Bone of Mandibular Bilateral-Distal Extension Removable Partial Dentures Which Retained by Two Different Types Retention
原文传递
导出
摘要 用三维光弹性应力分析方法,对Thompson半精密附着体固位与RPI卡环固位下颌双侧游离端可摘局部义齿在牙槽骨内的应力分布进行了研究。同时,比较了两种不同固位方法的牙槽骨内的应力分布规律。获得了基牙根尖应力。 This paper applied 3-D photoelastic stress analysis method,studied the stress distribution on bone of mandibular bilateral-distal-extension removalbe partial dentures which retained by Thompson Dowel Semi precision attachment and RPI Assembly. Nearwhile,the stress distribution on bone by two diffrent types retention was compared. The stress of abutment apical was obtained.
出处 《武汉工业大学学报》 CSCD 1995年第4期80-82,90,共4页
关键词 可摘局部性 义齿 固位体 牙槽骨 应力 牙体修复 D photoeiastic denture removable partial thompson dowel semiprecision attachmentRPI assembly
  • 相关文献

参考文献1

二级参考文献1

同被引文献7

  • 1Lundgren D, Falk H, Laurell L. Influence of number and distrbution of occlusal cantilever contacts on closing and chewing forces in dentitions[J ]. J Prosthet Dent, 1977, 38: 123.
  • 2Tsau Mau Chou. Photoelastic analysis and comparison of Force - transmission tharact~'istics of intracoronal attachments with clasp distal-extension removable partial dentures[J] .J Prosthodont, 1989,9: 313- 9.~.
  • 3Theodore Berg. Maxillary distal - extension removable partiald enture abutments with reduced periodontal support[J] . J Prosthodont, 1993; 9: 245- 50.
  • 4Craig RG, Farah JW. Stresses from loading distal - extension removable partial denture[J].J Prosthet Dent, 1978, 39:274-7.
  • 5Zinner ID. Locking type of semi - precision attachments[J ] .Dent Clin North Am, 19851299( 1 ) : 97- 155.
  • 6徐君伍主编.口腔修复临床与理论[M].北京:人民卫生出版社,1999.545-547.
  • 7王焱,米乃元,覃峰,刘付关平,陈锦安.游离端半精密附着体义齿的支持骨表面应力分析[J].中山医科大学学报,2000,21(3):219-222. 被引量:52