摘要
采用氢化物-AAS法测定了矿样和水样中的微量铅.研究了WF-Ⅱ型氢化物发生器与WYX-401型原子吸收分光光度计联用,测定铅的最佳工作条件,提出了盐酸-硼氢化钠-铁氰化钾体系发生铅化氢.测得标样回收率为95.6%~101.0%.变动系数为7.05×10 ̄(-2)%.
A simple and sensitive method for the determination of lead in water and mineral by WF-Ⅱ Hy-dride generation was improved.The improved system of hydragep chloride-potassium ferricyanide-sodium borohydide was adopted to evolve the hydride of lead and to determine micro amounts of Pb ̄(2+) inwatet and mineral.The recoveries of standard samples are 95.6%,101.0%,The RSD are 7.05 ×10 ̄(-2)%.
出处
《西南师范大学学报(自然科学版)》
CAS
CSCD
1995年第1期97-100,共4页
Journal of Southwest China Normal University(Natural Science Edition)
关键词
氢化物
原子吸收光谱
铁氰化钾
铅
水
矿物
hydride
atomic absorption spectrometry
potassium ferricyanide
determinafion of lead