中国计量科学研究院(NIM)的直流电动势副基准经多次与国内外约瑟夫森电压标准比对表明,七年中最大累积变化约为0.21×10-6,平均每年变化仅0.03uV.从1995年1月1日起改值0.20×10-6后,可与国际电压值在3×10-8误差范围内保持一致.
It has been shown by comparison between secondary standard ofDC EMF at NIM and Josephson-effect standard in the country and abroadthat the maximum accumulating veriation in 7 years is about 0.21×10-9,and the average change is only 0.03μV/year. After changing the value of0.20×0-9 it can coincide with international voltage value in a range oferrors 5×10-8.