纯铁片植入45只兔眼玻璃体,1天~12周取出。火焰原子吸收分光光度法测定房水、玻璃体Fe、Cu、Zn含量。铁植入后,房水、玻璃体Fe值增高,玻璃体Cu值增高;玻璃体Zn值低于正常,且对照组单纯穿通伤玻璃体Zn值亦较正常低。铁取出后10周,房水、玻璃体Fe值下降,但铁存留8~12周组玻璃体Fe、Cu值仍较高。探讨了铁异物存留时间及其取出后与房水、玻璃体Fe、Cu、Zn值的关系和机理。
he pieces of pure iron were
implanted into the vitreous cavity of 45 rabbits and extracted during
1 day to 12 weeks. The iron,copper and zinc contents in the aqueous
and vitreous were analysed by the atomic ab-sorption
spectrophotometer. The results showed that following implantation the
iron contents in the aqueous and vitreous and the copper contents in
the vitreous increased, and zinc levels in the vitreous of both
experi-mental eyes and merely perforating eyes in the control were
lower than those in normal eyes. After ten weeks of extraction of the
iron,a decrease of iron contents was presented,but the iron and
copper levels in the vi-treous which had contained the iron for 8 to
12 weeks were higher.The relation between the time of the
im-plantation and extraction of iron foreign bodies and the
quantities of iron,copper,and zinc in aqueous and vi-treous,and the
mechanism are discussed.