摘要
用HPGeγ谱仪与低本底NaI(T1)γ谱仪相结合,通过测量放射性废水中 ̄(90)Sr- ̄(90)Y发射的高能电子与探测器作用所产生的韧致辐射,确定 ̄(90)Sr含量。运用本方法取样测量了中国原子能科学研究院积存的7种放时性废水样品。5种废水中 ̄(90)Sr含量的测量结果与放化法测量结果在10%以内相符。
A direct wav is found to determine the content of  ̄(90)Sr in radioactive waste waters. Witj thecombination of HPGe γ spcetrometer and low background NaI(T)γ spectrometer,the contents of ̄(90)Sr in radioactive waste waters arising from CIAE are determined by measuring the intensity ofbremsstrahlung produced from ̄(90)Sr- ̄(90)Y. The measured results of five kinds of waste water areagreeable to those by radiochemical analvsis within 10 %.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
1995年第6期529-533,共5页
Atomic Energy Science and Technology